CivilTech | Home | Software | Contact Us | About Us | Our Location | Tech Support
HOME

    Software
       AllPile
       Shoring
       LiquefyPro
       SuperLog
       EarthPres
       Surcharge
       Heave
       Visual Lab
       Spectra
       Upres

    Order
    Download
    Pricing
    Contact Us
    About Us
    Q & A


Software Q&A




General Questions

 
How can I change printers?
For some computers, you cannot change your printer when the program is open.
If you want to change printer, you need to do following:
1. Close the program.
2. In Windows, click Start, go to Settings, then Printers
3. Find the new printer you want, and make it the default printer
4. Open the program again.
03 Feb 2005 by James

<< Previous 1 2 3 Next >>


AllPile Questions

 

<< Previous 1 2 Next >>


Shoring Questions

 
After I worked with one module, I cannot find the other modules.
You can go to top manual and click View/All Modules. It opens all modules. You can also open the general module and find many options in Item 9, or go to page B to open each module.
05 Jun 2007 by James

Can users save the files of each module together?
Users can save files in each module individually. Alternatively, users can save project file in General module, which will save all files of each module together. However, the project file keeps only the location and name of each module files, and does not actually save the data. If users move or delete one module file, the project file loses the module file. It is recommended to save files individually for each module.
05 Jun 2007 by James

Where to change unit?
In General module, Page A, Item 6. Once you select unit, the entire 4 modules use the same unit.
In most condition, the force is in kip or kN; the length, diameter, or depth is feet or m,
Except deflection is in. or cm; unit weight is pcf or kN/m3.
17 Jul 2006 by James

What Factor of Safety should be inputted? Where to input?
There are two places to input F.S. You only need to input one place.
1. In Earthpres module, Page E, Options, Item 4 and 5, you can input Factor for both active and passive pressures. If soil parameters are allowable, you do not input additional factors. For example, a soil has allowable friction =30 and ultimate friction=38. When you input friction=30, you do not need input additional factors. The output pressures are allowable pressures.

2. In Shoring module, Page D, Options, Item 15, you can input F.S. It only applies to passive pressures and increase pile embedment. It does not affect active pressure.
If the pressures are allowable, you do not input F.S. If the pressures are ultimate, you need input F.S. A typical value of 1.5 is commonly used for temporary shoring.

Whether the soil parameters or pressures are allowable, please check with your geotechnical engineers.
17 Jul 2006 by James

Can Shoring V8 open V6 and V7 files?
Yes, it can. In Shoring module at open file dialog screen, select V6 and V7 from [Files of Type].
05 Jan 2006 by James

<< Previous 1 2 3 4 Next >>